Unloading valve -RL
Setting pressure :0.68 to 15.5 bar @ 20 C (10 to 225 psig @ 70°F)
Maximum outlet pressure :15.5 bar (225 psig)
Preset pressure = required pressure -0.8 x back pressure
Operating temperature :-23℃ to 148℃(-10 ℃ to 300°F)
Can be applied to gas or liquid
Adjustable valve cap, adjustable opening pressure
Anti-loose wire hole can effectively maintain the set opening pressure
A variety of sealing materials are available