产品展示

Product Center

current position: Home > Product Center > A tube valve

Product Center Product

contact usContact Us

SMYTIK (Kunshan) Precision Machinery Co.,Ltd

Contact person: Liu Zong

Mobile phone number: 19951158023

Email: lsy@smytikgroup.com

Website: www.smytikgroup.com

Address: Room 304, Room 8, No.1911, Shuixiu Road, Kunshan City, Jiangsu Province


S6-MF8-N4-TB04-FN04-T

S6-MF8-N4-TB04-FN04-T

  • Category:A tube valve
  • Browse number:
  • QR code:
  • Release time:2022-03-02 16:33:58
  • Product description

Table tube valve


The process and instrument line are combined on the same valve body


1/4 NPT female thread standard release port


1/2 NPT female thread standard export




Isolate the release valve set


Pressure equal volume refer to ASME B16.34


Handle colors have functional partitions


Ball valve and needle valve diversity combination structure


Material traceability


Each valve is factory tested in accordance with EN 12266 or API Std 598


Flange ports may be selected in accordance with ASME B16.5, EN 1092-1


The release port has a plug


Compared with traditional design, it saves weight, space and cost




Ball valve characteristics


The highest stress level is Class2500


Operating temperature :-54℃ to 232℃ (-65°F to 450°F)


Quarter turn open and close operation


The pointing block shows the open or closed position


Bottom load stem structure to prevent stem out, improve system safety


High strength stem bearing support provides smooth opening and closing and eliminates friction between stem and body


Valve packing may need to be adjusted during service


SMYTIK ball valves are designed for use in fully open or fully closed positions



Needle valve characteristics


The highest pressure level is Class4500


PTFE packing :-54℃ to 232℃ (-65°F to 450°F)


Graphite packing :-54℃ to 649℃ (-65°F to 1200°F)


Two stem stem design:


The upper valve stem thread is hardened by rolling and the lower valve stem surface is specially hardened


The grease on the upper stem threads is isolated from the system medium


The non-rotating lower stem up and down movement replaces the rotary lift, avoiding friction between the seat sealing surface and the valve head, and greatly reducing friction between the lower stem and the packing


The valve stem has the back sealing function in the fully open position. The handle is locked by screws at both ends, which is stable and durable



OS&Y needle structure

The highest pressure level is Class4500


PTFE packing :-54℃ to 232℃ (-65°F to 450°F)


Graphite packing :-54℃ to 649℃ (-65°F to 1200°F)


Two stem stem design:


The upper valve stem thread is rolled and hardened, and the lower valve stem surface is isolated from the system medium by the grease specially hardened upper valve stem thread


Non-rotating lower stem up and down movement instead of rotary lifting, avoid seat sealing surface and valve head friction, and greatly reduce the friction between the lower stem and packing valve cap bolt connection, good strength, high reliability


The valve stem has the function of back sealing, and can prevent the valve stem from being blown out by the medium pressure adjustable packing gland easy to adjust the packing gland to form an effective seal unibody forged valve cap bracket high strength, and ensure that the valve stem completely concentric handle with two screws locking, durable



Rules of coding